<parameter name= "BAT_ADC_CHANNEL" default= "-1" type= "INT32" >
<short_desc > This parameter is deprecated. Please use BAT1_ADC_CHANNEL</short_desc>
</parameter>
<parameter name= "BAT_A_PER_V" default= "-1.0" type= "FLOAT" >
<short_desc > This parameter is deprecated. Please use BAT1_A_PER_V</short_desc>
<decimal > 8</decimal>
</parameter>
<parameter name= "BAT_CAPACITY" default= "-1.0" type= "FLOAT" >
<short_desc > This parameter is deprecated. Please use BAT1_CAPACITY instead</short_desc>
<long_desc > Defines the capacity of battery 1.</long_desc>
<min > -1.0</min>
<max > 100000</max>
<unit > mAh</unit>
<decimal > 0</decimal>
<increment > 50</increment>
<reboot_required > true</reboot_required>
</parameter>
<parameter name= "BAT_CRIT_THR" default= "0.07" type= "FLOAT" >
<short_desc > Critical threshold</short_desc>
<long_desc > Sets the threshold when the battery will be reported as critically low. This has to be lower than the low threshold. This threshold commonly will trigger RTL.</long_desc>
@ -752,78 +738,6 @@
@@ -752,78 +738,6 @@
<increment > 0.01</increment>
<reboot_required > true</reboot_required>
</parameter>
<parameter name= "BAT_N_CELLS" default= "0" type= "INT32" >
<short_desc > This parameter is deprecated. Please use BAT1_N_CELLS instead</short_desc>
<long_desc > Defines the number of cells the attached battery consists of.</long_desc>
<unit > S</unit>
<reboot_required > true</reboot_required>
<values >
<value code= "0" > Unconfigured</value>
<value code= "2" > 2S Battery</value>
<value code= "3" > 3S Battery</value>
<value code= "4" > 4S Battery</value>
<value code= "5" > 5S Battery</value>
<value code= "6" > 6S Battery</value>
<value code= "7" > 7S Battery</value>
<value code= "8" > 8S Battery</value>
<value code= "9" > 9S Battery</value>
<value code= "10" > 10S Battery</value>
<value code= "11" > 11S Battery</value>
<value code= "12" > 12S Battery</value>
<value code= "13" > 13S Battery</value>
<value code= "14" > 14S Battery</value>
<value code= "15" > 15S Battery</value>
<value code= "16" > 16S Battery</value>
</values>
</parameter>
<parameter name= "BAT_R_INTERNAL" default= "-1.0" type= "FLOAT" >
<short_desc > This parameter is deprecated. Please use BAT1_R_INTERNAL instead</short_desc>
<long_desc > If non-negative, then this will be used in place of BAT_V_LOAD_DROP for all calculations.</long_desc>
<min > -1.0</min>
<max > 0.2</max>
<unit > Ohm</unit>
<reboot_required > true</reboot_required>
</parameter>
<parameter name= "BAT_SOURCE" default= "0" type= "INT32" >
<short_desc > This parameter is deprecated. Please use BAT1_SOURCE instead</short_desc>
<long_desc > Battery monitoring source. This parameter controls the source of battery data. The value 'Power Module' means that measurements are expected to come from a power module. If the value is set to 'External' then the system expects to receive mavlink battery status messages.</long_desc>
<min > 0</min>
<max > 1</max>
<values >
<value code= "0" > Power Module</value>
<value code= "1" > External</value>
</values>
</parameter>
<parameter name= "BAT_V_CHARGED" default= "4.05" type= "FLOAT" >
<short_desc > This parameter is deprecated. Please use BAT1_V_CHARGED instead</short_desc>
<long_desc > Defines the voltage where a single cell of battery 1 is considered full under a mild load. This will never be the nominal voltage of 4.2V</long_desc>
<unit > V</unit>
<decimal > 2</decimal>
<increment > 0.01</increment>
<reboot_required > true</reboot_required>
</parameter>
<parameter name= "BAT_V_DIV" default= "-1.0" type= "FLOAT" >
<short_desc > This parameter is deprecated. Please use BAT1_V_DIV</short_desc>
<decimal > 8</decimal>
</parameter>
<parameter name= "BAT_V_EMPTY" default= "3.5" type= "FLOAT" >
<short_desc > This parameter is deprecated. Please use BAT1_V_EMPTY instead</short_desc>
<long_desc > Defines the voltage where a single cell of battery 1 is considered empty. The voltage should be chosen before the steep dropoff to 2.8V. A typical lithium battery can only be discharged down to 10% before it drops off to a voltage level damaging the cells.</long_desc>
<unit > V</unit>
<decimal > 2</decimal>
<increment > 0.01</increment>
<reboot_required > true</reboot_required>
</parameter>
<parameter name= "BAT_V_LOAD_DROP" default= "0.3" type= "FLOAT" >
<short_desc > This parameter is deprecated. Please use BAT1_V_LOAD_DROP instead</short_desc>
<long_desc > This implicitely defines the internal resistance to maximum current ratio for battery 1 and assumes linearity. A good value to use is the difference between the 5C and 20-25C load. Not used if BAT_R_INTERNAL is set.</long_desc>
<min > 0.07</min>
<max > 0.5</max>
<unit > V</unit>
<decimal > 2</decimal>
<increment > 0.01</increment>
<reboot_required > true</reboot_required>
</parameter>
<parameter name= "BAT_V_OFFS_CURR" default= "0.0" type= "FLOAT" >
<short_desc > Offset in volt as seen by the ADC input of the current sensor</short_desc>
<long_desc > This offset will be subtracted before calculating the battery current based on the voltage.</long_desc>
@ -10444,36 +10358,36 @@
@@ -10444,36 +10358,36 @@
</parameter>
</group>
<group name= "Sensors" >
<parameter name= "BATMON_ADDR_DFLT" default= "11" type= "INT32 " >
<short_desc > I2C address for BatMon battery 1 </short_desc>
<parameter name= "BAT1_C_MULT" default= "1.0" type= "FLOAT " >
<short_desc > Capacity/current multiplier for high-current capable SMBUS battery </short_desc>
<decimal > 1</decimal>
<reboot_required > true</reboot_required>
</parameter>
<parameter name= "BATMON_DRIVER_EN " default= "0" type= "INT32" >
<short_desc > Parameter to enable BatMon module </short_desc>
<parameter name= "BAT1_SMBUS_MODEL " default= "0" type= "INT32" >
<short_desc > Battery device model </short_desc>
<min > 0</min>
<max > 2</max>
<reboot_required > true</reboot_required>
<values >
<value code= "0" > Disabled </value>
<value code= "1" > Start on default I2C addr(BATMON_ADDR_DFLT) </value>
<value code= "2" > Autodetect I2C address (TODO) </value>
<value code= "0" > AutoDetect </value>
<value code= "1" > BQ40Z50 based </value>
<value code= "2" > BQ40Z80 based </value>
</values>
</parameter>
<parameter name= "BAT_C_MULT" default= "1.0" type= "FLOAT " >
<short_desc > Capacity/current multiplier for high-current capable SMBUS battery </short_desc>
<parameter name= "BATMON_ADDR_DFLT" default= "11" type= "INT32 " >
<short_desc > I2C address for BatMon battery 1 </short_desc>
<decimal > 1</decimal>
<reboot_required > true</reboot_required>
</parameter>
<parameter name= "BAT_SMBUS_MODEL " default= "0" type= "INT32" >
<short_desc > Battery device model </short_desc>
<parameter name= "BATMON_DRIVER_EN " default= "0" type= "INT32" >
<short_desc > Parameter to enable BatMon module </short_desc>
<min > 0</min>
<max > 2</max>
<reboot_required > true</reboot_required>
<values >
<value code= "0" > AutoDetect </value>
<value code= "1" > BQ40Z50 based </value>
<value code= "2" > BQ40Z80 based </value>
<value code= "0" > Disabled </value>
<value code= "1" > Start on default I2C addr(BATMON_ADDR_DFLT) </value>
<value code= "2" > Autodetect I2C address (TODO) </value>
</values>
</parameter>
<parameter name= "CAL_AIR_CMODEL" default= "0" type= "INT32" >